Product Details: Place of Origin:ChinaBrand Name:LEADING Certification:CE Model Number:L932-B Payment & Shipping Terms: MinimumOrderQuantity:1Set Price:Negotiable PackagingDetails:Carton Delivery Time:30-35 days Payment Terms:D/A, L/C, D/A, D/P, T/T Supply Ability:5000 Pcs / Each Month |
Detailed Product Description
Phase: |
Three Phase |
Pump Controlled Quantity: |
Two Pumps |
Enclosure Protection Grade: |
IP54 |
Install Position: |
Wall Mounting |
Displaying : |
LCD Display |
Liquid Level Transfer Distance: |
≤1000m |
Digital Three Phase Duplex Booster Water Pump Controller - Auto And Manual, 0.75-15KW ,With One Button Calibration.
Model: L932-B
Products Brief :
Intelligent Three Phase Duplex Booster Pump Controller AC380V Input Voltage , DOL Start Type , One Button Calibration. L932-B Booster Pump controller ,is an intelligent three phase fully automatic pump controller with built-in water level control.
It can be helpful in booster water applications, It comes in an ABS enclosure for weather-proof installation. It is suitable for Auto/Manual operation.
Main Technical Specifications
■Rated Input Voltage…………………………………………………AC380V / Three Phase
■ Rated Frequency…………………………………………50Hz-60Hz (at option)
■ Rated Output Power of Motor…………………0.75-4KW / 5.5-11KW/15KW(at option)
■ Open Phase Trip Response Time…….……………………2sec
■ Short Circuit Trip Response Time……………………………………………0.1sec
■ Dry Running Trip Response Time………………………………………………6sec
■ Over / Under Voltage Trip Response Time……………………………………5sec
■ Pump Stalled Trip Response Time……………………..………0.5sec
■ Over Current Trip Response Time……………………………………5sec-5min
■ Recovery Time of Over / Under Voltage……………………………………2min
■ Recovery Time of Over Current…………………………………………30min
■ Recovery Time of Dry Running.………………………………………………30min
■ Over / Under Voltage Trip……..……………………………….………………±15%
■ Dry Running Trip……………………………………………….70%
■ Pump Stalled Trip………………………………………….……………………200%
① the Characteristic of Inverse-time, the stronger of the current, The shorter of trip response time
② Percent of rated input voltage ( i.e if the rated input voltage is 380V, the Over voltage trip is 437V, the Under voltage trip is 323V)
③ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, the dry running trip ampere is 7A)
④ Percent of load time of calibration ( i.e if the running ampere of pump motor is 10A during the calibration, The pump stalled trip ampere is 20A)
Application |
Control & protect booster pump only |
Model |
L932-B |
Start type |
Direct on line |
Qty of controlled pump |
Duplex pump |
Rated input voltage: |
AC380V Three phase 50HZ/ 60HZ |
Rated output power: |
0. 75kw-4kw (1 hp-5. 5hp) 15kw (20hp) |
Protection function |
Over load protection Pump stalled protection Dry run protection Under voltage protection Over voltage protection Repeat start protection Phase unbalance protection Phase reversal protection Open phase protection |
Control characteristic |
Connecting 0.5-4.5V pressure transmitter to replace pressure switch Duplex pump control .Main pump / standby pump automatically alternate .Main pump / standby pump automatically switch against malfunction .Standby pump participate running if required |
Other features |
LCD screen displaying dynamic real time pressure value & pump running status Pump accumulative running time recording Pump last five faults record displaying Presenting one dry contact point (BA port) Present RS485 port Present user remote monitor LCD screen locked function under Auto state Push button calibration |
Working temperature Working humidity Degree of protection Install position Unit dimension (L x W x H) |
-25℃-- +55℃ 20%--90%RH, no drips concreted IP54 Wall mounting 310 x 220x 1 20mm |
Product Application:
Tag: duplex pump control panel, duplex alternating pump controller
FAQ:
Q1.Can I get some samples?
A1:Yes, Sample order is available for quality check and market test.
Q2.What's delivery time?
A2:It usually takes about 3-5 working days for small order and 10-15 days for big order.
Q3.What's your payment terms?
A3:We usually accept all kinds of payment terms .Such as T/T,L/C, PayPal
Q4.What's your warranty terms?
A4:We offer 16 months warranty time.
Q5.Do you have the products in stock?
A5:Depends on your request, We have standard models in stock. Some special products and big order will be newly produced according to your order quantity.
Q6.How does your factory do the quality control?
A6:Quality is priority, we always attach the importance to quality control from the beginning to the end of the production. every product will be fully assembled and carefully tested before packing and shipping.